PEGADA DE CARBONO E PEGADA HÍDRICA EM SISTEMA INTEGRADO DE ANAEROBIOSE + WETLAND CONSTRUÍDO DE FLUXO LIVRE COM SUPORTE FLUTUANTE + O3 NO TRATAMENTO DE EFLUENTES URBANOS

Authors

DOI:

https://doi.org/10.17058/tecnolog.v26i2.17664

Abstract

The application and evaluation of built-in Wetlands integrated systems was made considering the values ​​of CO2eq and depletion of gray and blue waters in m3. The analyzes considered were Total Organic Carbon - TOC and Total Nitrogen - NT, associating the values ​​of CO2-C; CH4-C and N2O-N. The process of this evaluation considered the integrated system Anaerobic Reactor + Wetland Constructed Floating Free Flow (WCFLF) + O3, in bench unit. The integration of the system involved the use of the macrophytes Hymenachne grumosa and Pistia stratiotes, where it was monitored aiming at the adequacy of potential reuse of wastewater. Ozonation was also applied in bench and pilot unit reactors, in the first case with air diffuser from a pneumatic pump and with application rates of 80 mg O3 L-1 effluent-1 h-1, both in batch regime. For the tests in the pilot unit, a centrifugal pump with a Venturi-type system was applied for O3 diffusion, with a re circulation time of up to 4 hours. For the reference flow of 400 L, the balance values ​​of CO2-C, CH4-C and N2O-N (mg m-2 week-1) were 17622.1; 6263.4 and 47.3, respectively. As for the water footprint, the reduction in relation to the polluting load of the raw effluent was 64.4%, with treated effluent considering a flow of 135.60 m3 month-1. Therefore, the developed integrated system presented environmental sustainability regarding the parameters studied.

 

Keywords: Constructed Wetlands. Floating Free Flow. Hymenachne grumosa. Pistia stratiotes. Ozonation.

Downloads

Download data is not yet available.

References

FILHO, D. R. S. et al. Análise dos indicadores de saneamento básico e seus impactos sobre a saúde pública e coletiva em Aparecida de Goiânia, Goiás. Brazilian Journal of Health Review, vol. 5, n. 2, p. 5407-5427. DOI:10.34119/bjhrv5n2-121, 2022.

TEIXEIRA, J. C; GOMES, M. H. R; SOUZA, J. A. Associação entre cobertura por serviços de saneamento e indicadores epidemiológicos nos países da América Latina: estudo com dados secundários. Revista Panamericana de Salud Pública, vol. 32, p. 419-425, 2012.

SILVA, S. A. et al. Saneamento básico e saúde pública na bacia hidrográfica do Riacho Reginaldo em Maceió, Alagoas. Engenharia Sanitária e Ambiental, Rio de Janeiro, vol. 22, n. 4, p. 699-709. ISSN 1809-4457. DOI: 10.1590/S1413-41522017146971, 2017.

FERREIRA, Y. B. C. Proposição de um índice de vulnerabilidade humana à insuficiência de saneamento básico em municípios de pequeno porte: a experiência do estado da Paraíba. Dissertação (Mestrado em Engenharia Civil e Ambiental) - Universidade Federal de Campina Grande. Campina Grande, PB, 2020.

TRATA BRASIL. 2021. Esgoto. Disponível em: http://www.tratabrasil.org.br/saneamento/principais-estatisticas/no-brasil/esgoto.

BRASIL. Ministério do Desenvolvimento Regional. Secretaria Nacional de Saneamento – SNS. Sistema Nacional de Informações sobre Saneamento: 25º Diagnóstico dos Serviços de Água e Esgotos – 2019. Brasília: SNS/MDR, 2020. 183 p.: il.

PLANSAB, Plano Nacional de Saneamento Básico. 2019. Disponível em < https://antigo.mdr.gov.br/images/stories/ArquivosSDRU/ArquivosPDF/Versao_Conselhos_Resolu%C3%A7%C3%A3o_Alta_-_Capa_Atualizada.pdf > acesso em 12 de maio de 2021.

SUBTIL, E.; SANCHEZ, A.; CAVALHERO, A. (2016). Sistemas descentralizados de tratamento de esgoto e reuso de água. In book: Ciência e Tecnologia Ambiental: Conceitos e Perspectivas (pp. 201 - 220). Chapter: 9. Publisher: Editora UFABC.

CHEN, H-S. Establishment and Applied Research on Wetland Ecosystem Evaluation Model in Taiwan Sustainability, vol. 7, 15785–15793; doi:10.3390/su71215785, 2015.

PENRU, Y; ANTONIUCCI, D; AMORES BARRERO, M. J.; CHEVAUCHÉ, C. Water footprint calculation: application to urban water cycle. Int J Interact Des Manuf, v. 10, p. 213–216 DOI 10.1007/s12008-016-0327-2, 2016.

MANDER Ü.; DOTRO, G.; EBIE, Y.; TOWPRAYOON, S.; CHIEMCHAISRI, C.; NOGUEIRA, S.F.; JAMSRANJAV, B.; KASAK, K.; TRUU, J.; TOURNEBIZE, J.; MITSCH, W. J. Greenhouse gas emission in constructed wetlands for wastewater treatment: A review http://dx.doi.org/10.1016/j.ecoleng.2013.12.006 , 2013.

SALIBA, P. D.; von SPERLING, M.; Performance evaluation of a large sewage treatment plant in Brazil, consisting of a UASB reactor followed by activated sludge. Water Science & Technology, 2017.

TRIPATHI, S; TRIPATHI, D. M.; TRIPATHI, B. D. Removal of Organic Content and Color from Secondary Treated Wastewater in Reference with Toxic Potential of Ozone During Ozonation. Hydrology Current Research, 2011. Disponível em: http://dx.doi.org/10.4172/2157-7587.1000111.

SHARIF, F. Use of Ozonation and Constructed Wetlands to Remove Contaminants of Emerging Concern from Wastewater Effluent. A Dissertation Presented in Partial Fulfillment of the Requirements for the Degree Doctor of Philosophy, August, 228 p., 2013.

SALLANKO, J.; OKKONEN, J. Effect of ozonation on treated municipal wastewater. Journal of environmental science and health. Part A, Toxic/hazardous substances & environmental engineering, vol. 44, p. 57-61. 10.1080/10934520802515350, 2009.

HORN, T. B.; ZERWES, F. V.; KIST, L. T.; MACHADO, Ê. L. Constructed wetland and photocatalytic ozonation for university sewage treatment. Ecological Engineering, vol. 63, p. 134-141. https://doi.org/10.1016/j.ecoleng.2013.12.012, 2014.

MIRANDA, N. D.; OLIVEIRA, E. L.; SILVA, G. H. R. Study of constructed wetlands effluent disinfected with ozone. Water Science And Technology. London: Iwa Publishing, vol. 70, n. 1, p. 108-113, 2014. Disponível em: <http://hdl.handle.net/11449/117456>.

CONSEMA. CONSELHO ESTADUAL DE MEIO AMBIENTE - Resolução n. 355/2017. Disponível em: http://www.sema.rs.gov.br/upload/arquivos/201707/19110149-355-2017-criterios-e-padroes-de-emissao-de-efluentes-liquidos.pdf.

ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 13969: projeto, construção e operação de unidades de tratamento complementares e disposição final dos efluentes de tanques sépticos: procedimentos. Rio de Janeiro, 1997.

MORERA; L, et al. Water footprint assessment in wastewater treatment plants. Journal of Cleaner Production, vol. 112, p. 4741 e 4748, 2016.

DUPONT, A. Avaliação da eficiência da Estação de Tratamento de Esgoto da Universidade de Santa Cruz do Sul, RS, Brasil. 2010. 159 f. Dissertação (Programa de PósGraduação em Tecnologia Ambiental) - Universidade de Santa Cruz do Sul, Santa Cruz do Sul, 2010.

APHA/AWWA – AMERICAN PUBLIC HEALTH ASSOCIATION. Standard Methods for the Examination of Water and Wastewater. 22. ed. Washington: APHA/AWWA/WEF, 2012.

FLAMM, D. L. Analysis of ozone at low concentrations with boric acid buffered potassium iodide. Environ. Sci. Technol., vol. 11, p. 978–983, 1977.

CONAMA. Conselho Nacional do Meio Ambiente. RESOLUÇÃO Nº 357, DE 17 DE MARÇO DE 2005. Dispõe sobre a classificação dos corpos de água e diretrizes ambientais para o seu enquadramento, bem como estabelece as condições e padrões de lançamento de efluentes, e dá outras providências.

DRH/SEMA. Departamento de Recursos Hídricos/Secretaria Estadual de Meio Ambiente. Consolidação do Conhecimento sobre os Recursos Hídricos da Bacia do Rio Pardo e Elaboração do Programa de Ações da Sub-Bacia do Rio Pardinho, 2004.

Published

2022-12-05

How to Cite

Mesacasa, L., Taufer Fochi, D. A. ., Daltoé, M. F. ., & Machado, Ênio L. . (2022). PEGADA DE CARBONO E PEGADA HÍDRICA EM SISTEMA INTEGRADO DE ANAEROBIOSE + WETLAND CONSTRUÍDO DE FLUXO LIVRE COM SUPORTE FLUTUANTE + O3 NO TRATAMENTO DE EFLUENTES URBANOS. Tecno-Lógica, 26(2), 256-261. https://doi.org/10.17058/tecnolog.v26i2.17664

Issue

Section

Notas Técnicas